Standard IEC 60332-1-3-ed.1.0 15.7.2004 preview

IEC 60332-1-3-ed.1.0

Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles



STANDARD published on 15.7.2004


Language
Format
AvailabilityIN STOCK
Price52.80 USD excl. VAT
52.80 USD

The information about the standard:

Designation standards: IEC 60332-1-3-ed.1.0
Publication date standards: 15.7.2004
SKU: NS-409578
The number of pages: 21
Approximate weight : 63 g (0.14 lbs)
Country: International technical standard
Category: Technical standards IEC

Annotation of standard text IEC 60332-1-3-ed.1.0 :

IEC 60332-1-3:2004 Specifies a test procedure for assessment of falling flaming droplets/ particles when a single vertical electrical insulated conductor or cable, or optical fibre cable, is subjected to defined fire conditions. NOTE - Testing to IEC 60332-1-3 may be performed simultaneously with that to IEC 60332-1-2, if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-3 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm2 total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. IEC 60332-1-3:2004 Specifie une methode dessai pour evaluer les particules/gouttelettes enflammees tombant dun conducteur ou cable, ou dun cable a fibres optiques, lorsquil est soumis au feu dans des conditions definies. NOTE - Lessai de la CEI 60332-1-3 peut etre realise simultanement avec celui de la CEI 60332-1-2, si demande. LAnnexe A donne les recommandations pour les prescriptions de performance. La CEI 60332-1-3 donne des precisions sur lemploi dune flamme de type a premelange de 1 kW et est destinee a un usage general. Cependant la procedure specifiee peut ne pas convenir pour lessai sur conducteur ou cable de section totale inferieure a 0,5 mm2, car lame peut fondre avant la fin de lessai, ou bien encore pour lessai de petits cables a fibres optiques parce que le cable est rompu avant la fin de lessai.

These changes apply to this standard:

IEC 60332-1-3-ed.1.0/Amd.1 Change

Amendment 1 - Tests on electric and optical fibre cables under fire conditions - Part 1-3: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
(Amendement 1 - Essais des cables electriques et a fibres optiques soumis au feu - Partie 1-3: Essai de propagation verticale de la flamme sur conducteur ou cable isole - Procedure pour la determination des particules/gouttelettes enflammees)

Change published on 28.7.2015

Selected format:

Show all technical information.
26.40 USD


IN STOCK

We recommend:

Technical standards updating

Do you want to make sure you use only the valid technical standards?
We can offer you a solution which will provide you a monthly overview concerning the updating of standards which you use.

Would you like to know more? Look at this page.




Cookies Cookies

We need your consent to use the individual data so that you can see information about your interests, among other things. Click "OK" to give your consent.

You can refuse consent here.

Here you can customize your cookie settings according to your preferences.

We need your consent to use the individual data so that you can see information about your interests, among other things.